AgiBot quadruped robot operating on a US industrial site

Every grant below is public record. You can verify all of it yourself in about ninety seconds.

Short answer: The AgiBot X2, X2 Ultra, D1 Pro, D1 Edu, D1 Ultra and D1 Max hold FCC equipment authorization under grantee code 2BTPT, held by AgiBot Innovation (Shanghai) Technology Co., Ltd. All were granted before the FCC's 28 July 2026 rule change. Several other AgiBot models do not carry a host certification and should be treated as open questions until the responsible party is confirmed in writing.

"Is it FCC compliant?" is one of the first questions a serious robotics buyer asks, and it is usually answered badly. Vendors say yes. Buyers accept it. Nobody looks it up.

You can look it up. The FCC publishes its equipment authorization database at apps.fcc.gov/oetcf/eas, it is free, and it takes about ninety seconds. Here is what is actually in there for AgiBot, and what it does and does not mean.

The Grants, by Model

Model FCC ID Status
AgiBot X2 2BTPT-LX2501 Granted, pre-28 July 2026
AgiBot X2 Ultra 2BTPT-LX2501 Granted, pre-28 July 2026
AgiBot D1 Pro 2BTPT-ZYCXD105U Granted, pre-28 July 2026
AgiBot D1 Edu 2BTPT-ZYCXD105U Granted, pre-28 July 2026
AgiBot D1 Ultra 2BTPT-ZYCXD105U Granted, pre-28 July 2026
AgiBot D1 Max 2BTPT-ZYCXD125M Granted, pre-28 July 2026

Grantee code 2BTPT is registered to AgiBot Innovation (Shanghai) Technology Co., Ltd. Verify any of these directly at apps.fcc.gov/oetcf/eas by searching the grantee code.

Why the 28 July 2026 Date Matters

On 28 July 2026 the FCC's rule change affecting equipment from entities on the Covered List took effect. The practical consequence for buyers is that a grant issued before that date and a grant issued after it are not in the same position, and "the manufacturer says it is certified" is no longer a sufficient answer.

Every AgiBot grant listed above predates the rule change. That is a meaningful fact and it is checkable, which is the point: you should not take our word for it, and you should not take the manufacturer's word for it either.

What FCC Authorization Does Not Tell You

This is where most procurement conversations go wrong.

FCC equipment authorization is a radio-emissions question. It says the device's radios have been tested and authorized to operate in the United States. That is all it says.

NDAA procurement eligibility is a completely different regime. It governs whether a federal agency, or an organization spending federal funds, is permitted to buy a given piece of equipment based on its country of origin and supply chain. A device can hold a valid FCC grant and still be ineligible for federal purchase.

If you are buying with federal money, or if your grant conditions or state procurement rules reference country-of-origin restrictions, the FCC database will not answer your question. Ask your procurement office before you spec any robot, from any manufacturer.

The same distinction applies across the drone and robotics market generally. It is worth knowing which questions your compliance requirement is actually asking.

The Models We Will Not Claim Are Authorized

Being straight about this is more useful than a blanket yes.

Several AgiBot models, including the D1 MaxPro, A3, A3 Ultra and G2, do not carry an AgiBot host certification in the database. Where a product relies on a Supplier's Declaration of Conformity rather than a certification, US law requires a responsible party located in the United States, and if that party is not the manufacturer's US entity it defaults to the importer. That is a legal determination, not a paperwork step, and we do not treat it as settled until it is settled in writing.

We also found two models blank in the manufacturer's own compliance sheet. Blank is not the same as compliant.

We only list SKUs we have verified. If a model is not in our AgiBot collection, that is frequently the reason. Pricing for every model, listed and unlisted, is in our AgiBot price guide.

How to Check This Yourself

  1. Go to apps.fcc.gov/oetcf/eas and open the Grantee Code search.
  2. Enter the grantee code, which is the first three to five characters of the FCC ID. For AgiBot that is 2BTPT.
  3. Set the number of records to display high, then search on the grantee code alone.
  4. Read the grant date and the equipment class on each result.

One practical tip: searching by product code alone frequently returns "no applications on file" for grants that demonstrably exist. Search the grantee code and scan the list instead. We learned that the hard way.

Need compliance confirmed in writing?

If your procurement office needs the FCC grant, the model configuration and the importer of record documented before a purchase order, tell us the model and we will put it in writing alongside a formal quote.

Request a Quote

Request a Quote

Tell us what you need and we will get back to you with pricing, availability, and lead time.

Frequently Asked Questions

Is the AgiBot X2 FCC certified?
The X2 and X2 Ultra hold FCC ID 2BTPT-LX2501, granted before the 28 July 2026 rule change, under grantee code 2BTPT registered to AgiBot Innovation (Shanghai) Technology Co., Ltd.

Is the AgiBot D1 FCC certified?
The D1 Pro, D1 Edu and D1 Ultra share FCC ID 2BTPT-ZYCXD105U. The D1 Max holds 2BTPT-ZYCXD125M. All predate the 28 July 2026 rule change.

Does an FCC grant mean a robot is NDAA compliant?
No. They are separate regimes. FCC authorization covers radio emissions. NDAA eligibility covers federal procurement based on country of origin and supply chain. Confirm procurement eligibility separately with your own procurement office.

Do dexterous hands and grippers need an FCC ID?
The OmniHand and OmniPicker communicate over wired CAN-FD and RS485 rather than wireless links. Confirm the requirement for your specific configuration before deployment on a site with radio restrictions.

Can an FCC grant be revoked?
Yes. Equipment authorization is not permanent, and the database is the live record. Re-check before a large purchase rather than relying on a vendor page, including this one.

Keep Exploring

Grant data verified against the FCC Office of Engineering and Technology equipment authorization database. This article is general information, not legal or procurement advice. Confirm current status directly with the FCC and your own compliance office before purchase.

Latest Stories

This section doesn’t currently include any content. Add content to this section using the sidebar.